Washing Machine Outlet Box: Sizes, Code Heights and How to Install One (6 Boxes Compared From Spec Sheets)
A washing machine outlet box is a recessed wall box holding the hot and cold valves and a 2 inch drain hub. Mount it so the drain sits 18 to 42 inches above the trap weir (IPC 802.4.3); Oatey’s guide puts the box bottom 36 to 42 inches above the finished floor.
What does a washer box replace, and what stays the same?
A washer box replaces exposed valves and an open pipe end, while the plumbing behind it follows the same code as any standpipe. Under 2024 IPC Section 406.2, the washer must discharge through an air break into a standpipe or laundry sink, the trap and fixture drain must be at least 2 inches, and that drain must join a 3 inch or larger branch or stack. The box’s drain hub is simply the top of that standpipe, recessed into a 2×4 wall.
What the box adds is a home for both valves, a faceplate over the drywall cut, and a basin that sends drips to the drain; the Water-Tite DU-ALL has a raised drip guard for exactly that. For the height rules behind the wall, our page on standpipe height rules covers the trap weir measurement in detail.
Which washer box should you buy? Six boxes compared from maker spec sheets
Buy a box that matches your supply pipe (sweat, CPVC or a PEX standard), has a 2 inch drain and fits the stud bay; every dimension below is from the maker’s submittal or product page. Water-Tite and Guy Gray are both IPS Corporation brands, so the five names in most shopping lists come down to three makers.
| Box and part number | Box size (W x H x D) | Drain | Valves | Hammer arrestors | Fire rated |
|---|---|---|---|---|---|
| Oatey Quadtro 38545 | 9.43 x 9.61 x 3.73 in; opening 8.75 x 7.26 in | 2 in, PVC or ABS Sch. 40 DWV | Single lever, copper sweat | Yes, ASSE 1010 | No |
| Oatey Quadtro 38530 | Same Quadtro box | 2 in | Two 1/4 turn brass ball valves, copper sweat | No (38540 adds them) | No |
| Sioux Chief OxBox 696-G2313XF | 4 in single or 10 in double x 5-1/2 x 3-1/2 in; frame 11-1/2 x 7-1/4 in | 2 in Sch. 40 hub | 1/4 turn, F1807 PEX; handles throw together or separately | Yes, ASSE 1010 (2303 codes have none) | No |
| Sioux Chief OxBox 696RG2313XF | Same as 696; fire-rated ABS frame | 2 in Sch. 40 hub | 1/4 turn, F1807 PEX | Yes, ASSE 1010 | Yes, Warnock Hersey, 1 or 2 hour |
| Water-Tite DU-ALL 82052 (85630 single lever) | 8-3/8 x 6-1/8 x 3-3/8 in; faceplate 10-3/16 x 8-13/16 in | 2 in, right and left knockouts | 1/4 turn brass, 1/2 in sweat | Not listed | No |
| Guy Gray 82035 (NWBED200-4) | Rough opening 14 x 8-3/4 x 3-1/2 in; plate 15-3/4 x 9-1/2 in | 2 in, male threaded fitting | 1/2 in MIP/sweat valves | Not listed | Not listed; 20 gauge G90 steel |
Three things follow. First, none of these boxes offers a 1-1/2 inch drain: all six take a 2 inch drain, which is also the IPC 406.2 minimum. Second, depth runs 3-3/8 to 3.73 inches, so each one fits a 2×4 wall, whose actual 3-1/2 inch stud depth matches the Sioux Chief and Guy Gray boxes exactly. Third, width decides the retrofit cut: a 16 inch on-center bay of 1-1/2 inch studs leaves 14-1/2 inches clear, so the Guy Gray 14 inch rough opening has 1/4 inch to spare per side, while the 8-3/8 inch DU-ALL leaves about 6 inches.
The Guy Gray box is the one to pick if the dryer outlet must sit in the same wall plate: model 82035 carries a 4-wire 30 amp, 250 volt dryer receptacle plus a 20 amp duplex, which is work for a licensed electrician, not the plumber.

How high do you mount a washing machine outlet box?
Mount it so the drain hub lands 18 to 42 inches above the trap weir, then check that height against your washer’s manual. The code measures from the trap weir, not the floor; the floor numbers come from the box maker and the washer maker.
| Rule | Number | Source |
|---|---|---|
| Standpipe height above trap weir | 18 in minimum, 42 in maximum | 2024 IPC 802.4.3; same numbers in 2024 IRC P2706.1.2 |
| Standpipe when a laundry tray drains into it | 30 in minimum above the weir, tray outlet within 30 in horizontally | IPC 802.4.3.1, IRC P2706.1.2.1 |
| Trap and fixture drain size | 2 in minimum, into a 3 in or larger branch or stack | IPC 406.2 |
| Box bottom above finished floor | 36 to 42 in “normal”; 34 to 48 in “commonly” | Oatey supply box instruction guide; Oatey product FAQ |
| Top of standpipe, Whirlpool WTW5700XL | 39 in minimum; no higher than 96 in from bottom of washer; 4.5 in of hose maximum inside the pipe | Whirlpool dimension guide |
Neither the IPC nor the IRC text sets a trap height above the floor. California, Washington and other Uniform Plumbing Code states use UPC Section 804.1, which carries its own standpipe and trap limits; IAPMO keeps that text behind a login, so ask the building department for its numbers before framing.
The calculation no height chart shows is the trap weir window for a given box height. Inputs: treat the box drain hub as the top of the standpipe, so standpipe length equals box bottom height minus weir height, and that length must be 18 to 42 inches under IPC 802.4.3. Second input: Whirlpool’s 39 inch minimum for the WTW5700XL.
| Box bottom above floor | Allowed trap weir height (IPC) | Versus Whirlpool’s 39 in minimum |
|---|---|---|
| 34 in (Oatey FAQ low end) | Floor to 16 in | 5 in short |
| 36 in (Oatey guide low end) | Floor to 18 in | 3 in short |
| 39 in | Floor to 21 in | Meets it exactly |
| 42 in (Oatey guide high end) | Floor to 24 in | 3 in above |
| 48 in (Oatey FAQ high end) | 6 to 30 in | 9 in above |
The decision rule: for a WTW5700XL or any washer whose manual names a 39 inch minimum, set the box bottom at 39 to 42 inches, because the low half of Oatey’s range fails that manual. At 48 inches the trap weir has to sit at least 6 inches off the floor, or the standpipe exceeds the 42 inch IPC maximum. Measure from the rim of the drain hub you actually installed, since a hub that sits below the box floor shortens the standpipe by that amount.
Quarter-turn or single-lever valves, and when are hammer arrestors required?
Pick single-lever valves if the water will be shut off after every load, and pick a box with arrestors built in to satisfy IPC 604.9. A single-lever box, such as Oatey 38535 or Water-Tite 85630, closes hot and cold with one motion; Sioux Chief’s arrester models get close with two handles that its spec sheet says can be thrown together or separately. That matters most with rubber washing machine hoses, which stay under line pressure whenever the valves are open.
IPC Section 604.9 says a water hammer arrestor shall be installed where quick-closing valves are used and that arrestors shall conform to ASSE 1010. Oatey’s Quadtro submittal describes its arrestor option as the shock arrestor required on supply lines to quick-closing valves, and both Oatey and Sioux Chief list their arrestors as meeting ASSE 1010. Sioux Chief rates its valves and arrestors to 150 psig and 200 degrees F. If an older box drips at the stem or packing nut, our guide to a leaking washer shut off valve covers repair before you replace the whole box.

When does a washer box need to be fire rated?
A fire-rated box is needed when the laundry wall is itself a fire-resistance-rated assembly, such as a dwelling unit separation wall, because the box cuts a hole through the rating. The Sioux Chief 696R series is listed by Warnock Hersey under system design SC/WA120, and its design sheet sets these limits:
- 1 hour rating with a single layer of 5/8 inch gypsum; 2 hours with two layers, using the 696-EX frame extension.
- No more than 100 square inches of penetrations per 100 square feet of wall, on 16 or 24 inch stud spacing.
- Each box in its own stud bay and attached to the stud; the rating does not apply to two boxes in one bay, and boxes cannot go back to back.
- Drain of 2 inch or larger metallic, PVC or ABS DWV pipe.
Miss any one and the listing no longer covers the wall.

How do you install or replace a washing machine outlet box?
Install the box in 9 steps, with the drain test done before drywall goes up, following Oatey’s six-step instruction guide plus the code checks above:
- Shut off the house main and drain the lines; on a retrofit, close the old valves, disconnect the hoses and cut the drywall to the new box’s rough opening from the table.
- Measure the trap weir height and pick a box bottom height that keeps the standpipe at 18 to 42 inches above it and meets the washer manual.
- Attach the nailing brackets (Sioux Chief supplies an 18 inch bracket; Oatey sells 4 and 12 inch plastic brackets, parts 38768 and 38648) and set the box level on the stud.
- Solvent-cement the 2 inch drain into the box hub: Oatey says use ABS cement for ABS pipe and PVC cement for PVC pipe on its polystyrene boxes.
- Connect the 1/2 inch supplies to the valve bodies; Sioux Chief spaces its inlets 2 inches on center.
- Turn the water on and check every supply joint for leaks.
- Pressure test the DWV branch with the box’s test cap in place before drywall; Oatey says to ask local building officials for an approved method if a pressure test is not possible.
- Knock out the test cap, snap on the faceplate (Quadtro’s frame takes up to 1 inch of drywall) and connect the hoses.
- Hook the drain hose into the hub with no more than 4.5 inches inside, per Whirlpool, then run a cycle and watch for drips.
The common failures map to numbers: a standpipe under 18 inches above the weir, a hose pushed deeper than 4.5 inches or sealed into the hub with no air break (IPC 406.2 and IRC P2718.1 both require one), a 1-1/2 inch trap where 2 inches is the minimum, and a box with no arrestors on a quick-closing supply. A box set too low invites the siphoning that empties a tub mid-fill; if water backs up out of the box instead, the cause is downstream, and our washing machine drain guide traces it.
A drain pan does not replace the box; it catches leaks under the washer that the box drain never sees. Two boxes in the table give the pan line somewhere to go: Sioux Chief’s 696-CF secondary drainage funnel, sold separately, accepts 1/2, 3/4 or 1 inch CTS pipe through a knockout in the drain box, and IPS literature shows the DU-ALL in a “valves forward with auxiliary drain line” layout.
Washing machine outlet box questions
How high should a washing machine outlet box be?
Oatey’s supply box instruction guide calls 36 to 42 inches from the finished floor to the bottom of the box a normal height, and its product FAQ widens that to 34 to 48 inches. If your washer is a Whirlpool WTW5700XL, keep the box drain at 39 inches or higher to meet its dimension guide.
Can a washer box drain be 1-1/2 inch?
Not under the IPC. Section 406.2 requires the trap and fixture drain for a clothes washer standpipe to be at least 2 inches in diameter. Every box in the table above, from Oatey, Sioux Chief and IPS Water-Tite, ships with a 2 inch drain hub or fitting.
Do I need water hammer arrestors on a washer box?
IPC Section 604.9 requires a water hammer arrestor wherever quick-closing valves are used, and Oatey’s Quadtro submittal describes washer supply lines that way. Buying a box with ASSE 1010 arrestors built in, such as Oatey 38545 or Sioux Chief 696-G2313XF, covers it inside the box.
Does a washer box need to be fire rated?
Only when it sits in a fire-resistance-rated wall, such as a wall between dwelling units. A listed box like the Sioux Chief 696R series keeps the rating when installed per its design sheet, which allows 1 hour with one layer of 5/8 inch gypsum and 2 hours with two.
What is the difference between a washer box and a standpipe?
A standpipe is the vertical 2 inch pipe that rises 18 to 42 inches above its trap weir. A washer box is the recessed wall housing that holds the top of that standpipe plus the hot and cold valves, so the hose connections sit flush instead of in front of the wall.
How we sourced this
Box dimensions, drain sizes, valve types and listings come from the Oatey Quadtro submittal (LCS1216C 09/25), the Oatey supply box instruction guide, Sioux Chief 696 and 696R spec sheets, the IPS Water-Tite DU-ALL submittal (SPEC_WT_WMOB_82052-82014) and IPS product pages for Guy Gray 82035 and the MultiBox. Code text is the 2024 IPC and IRC as shown on UpCodes, and the 39 inch figure is from Whirlpool’s WTW5700XL dimension guide. The trap weir window table is our arithmetic from those numbers. Retail prices were left out because the retailer listings we tried could not be loaded, and UPC 804.1 numbers were left out because the IAPMO text was not viewable.