Rheem Heat Pump Water Heater Error Codes: All 40 From Rheem’s Own Manual
Rheem heat pump water heater error codes are four-character alarms such as A004 or T131. Rheem’s 2024 Gen V hybrid manual lists 40 of them: 12 switch heating to the electric elements and 18 disable the heater. E1, E2 and HP01, common online, appear in no Rheem hybrid manual.
Which Rheem manual covers your ProTerra: AP23657 or AP18095-2?
Two Rheem US use-and-care manuals carry the hybrid code charts; the form number at the bottom of each page tells you which is yours. AP23657 Rev 01 (copyright 2024) is the Gen V Universal Connect manual, with parts listed for 40, 50, 65 and 80 gallon tanks. AP18095-2 (dated 1/18) covers the earlier HB Duct Ready Series.
The control gives the generation away: the 2018 unit has a touchscreen with Settings, Status, Service and Mode tabs, while Gen V has Mode, Next, Clear Alarm and WiFi buttons plus a “!” fault icon. Rheem’s Performance Platinum ProTerra spec sheet (THD-PPEH5-30SO Rev. 8, 11/24) covers models XE40T10HS45U1 to XE80T10HS45U1.
Rheem hybrid code table: what keeps heating while each code stands
Every code in AP23657, with the heating result from Rheem’s “Possible Causes” column and the steps from its “What to Do” column, split by who does them.
| Code | Rheem’s wording | Heating while active | Owner step | Technician step |
|---|---|---|---|---|
| A004, A005 | Comp.Shutdown: Discharge-Suction Trip; Compressor Shutdown: Discharge Temp High | Elements (compressor malfunction) | Clean the filter screen | Confirm fan runs with compressor on; 60 V or more at the fan with no rotation means replace the fan; look for oily residue from a refrigerant leak |
| T005 | Compressor Shutdown: Discharge Temp High | Elements (low airflow) | Clean the filter screen | Same fan and leak checks |
| A006, T006 | Suction Temperature Too Low | Elements (compressor malfunction) | Clean the filter screen | Same checks; Rheem does not service sealed system parts, so a failed compressor means a new unit |
| A008 | Detected Dry Fire Condition | Heater disabled | Fill the tank and run a hot faucet to purge air; repeat while A008 remains | Rheem says board or sensor trouble would show a different code |
| A009, T009 | Compressor wiring may be faulty | Elements | None listed | Check wiring and sensor connections |
| A101, A102, A105, A106 | Suction, Ambient, Evaporator, Discharge Temp Sensor Failure | Elements | None listed | Ohm the thermistor against Rheem’s chart; Service, then Sensors, reads -40°F for an open circuit and +250°F for a short |
| A103, A104 | Lower, Upper Heater Temp Sensor Failure | Heater disabled | None listed | Same thermistor checks |
| A107 | Water Detected on Floor: Check For Leaks | Elements shut off; shutoff valve closes if fitted | Find and stop the leak first. Rheem’s override (hold Clear Alarm 5 seconds) restarts heating for 24 hours, so use it only once the leak is fixed or the rope is dry | Unplug the rope sensor; if the code clears, dry or replace the rope (part AP19134); if it persists with a new rope, replace the board |
| A108 | Condensate Blocked: Unclog Line | Elements | Clear the condensate line | Remove the top cover, inspect the pan; a dry pan with no blockage means replace the condensate sensor |
| A125, A126 | Lower, Upper Element Error or Relay Stuck Closed | Heater disabled | Shut off power | Ohm the element; a good reading means replace the board, a bad one the element |
| A127 | Element Wire Routing Error | Heater disabled | Shut off power | Confirm both wires at element and board, then ohm the element |
| A128, A129 | Lower, Upper Element Relay Failure to Close Error | Heater disabled | Shut off power | Check wiring and ohms, then board or relay |
| A130 | Unit Off/Air Temp Freezing: Enable Unit | Off until a mode is selected | Select a mode to turn it on | None listed |
| T131 | Clean Filter Reminder | Reminder only | Set Electric or OFF, wash the filter in mild detergent, dry, reinstall, reset the mode | None listed |
| T132 | Water Heater difficulty satisfying demand | Cannot keep up | Check for open faucets and leaks | Check sizing |
| A120 to A123 | Shutoff Valve can’t close, can’t open, inputs in error, not installed | Not stated | Unplug and replug the valve; with no valve fitted, set SOV to NO | Check wiring, then call Rheem customer service |
| A200 | High Water Temp! [ECO] Call Tech Service | Heater disabled | Shut off power | Check elements screw to ground and thermistor resistance, then the board |
| T300 | Water Leak Sensor Not Installed | Not stated | Plug in the rope sensor | Check sensor resistance to pick sensor or board |
| A502, A503, T504, A900, T901, A902 to A905 | Time Clock, WiFi Chip Communication Error, Controller Fault | Heater disabled | None listed | Replace the control board |
| A906 | Power Board Temp. Protection Sensor Failure | Not stated (controller too hot) | None listed | Replace the control board |
An element-default code (A004, A005, T005, A006, T006, A009, T009, A101, A102, A105, A106, A108) still gives hot water, on 4,500 W elements that Rheem’s mode chart rates “Very Low” for efficiency. A heater-disabled code means a cold tank. When you book service, quote the code and ask for a technician who reads the Service, Sensors screen and ohms the part before swapping a board.
How to find the code when a Rheem hybrid beeps but the screen shows no number
A beeping Rheem hybrid has a stored code in a menu, not on the home screen: Rheem’s 2024 manual says the unit beeps and lights the “!” icon when the board logs “either an Alarm or an Alert.”
- Gen V: press Next until “Current Alarm” appears, then press Down to scroll through each active code.
- 2018 touchscreen: tap the blinking Service button, then the blinking “alarms” button. The screen lists current alarms and a history of up to 6.
- Write the code down before clearing it with Clear Alarm. If the fault is real, it comes back.
Rheem documents only two beeps that are not faults: holding the WiFi button 3 seconds gives 1 beep (soft reset), 5 seconds gives 3 beeps (hard reset). A wet rope sensor also flashes the display backlight, per the 2018 manual.

Air filter, condensate line and room air: the codes an owner can clear
T131, T005, A108 and A130 are the four codes with tool-free owner steps, all tied to air or water around the heat pump section. For T131, set Electric or OFF, lift the filter out of its slot on top, wash it in mild detergent, dry it and drop it back. Rheem calls for 6 inches of clearance above the unit for this.
A108 means condensate is backing up. Rheem specifies a 3/4 inch NPT condensate connection, lines pitched at least 1/8 inch per foot, a P-trap on any sewer tie-in, and a condensate pump of at least 2 gallons per day where no drain exists. Once a year, pour a cup of bleach into the condensate tee to kill algae and mold.
Room air drives T005 and A130. Rheem’s spec sheet gives an ambient operating range of 37 to 145°F, the manual wants 700 cubic feet of open air for an unducted unit (450 at reduced output, with 2.3 square feet of louvers), and A130 appears below freezing. If the room cools more than 15°F while the compressor runs, Rheem says it needs more air, one of the room-air and cost trade-offs of a heat pump water heater.
Element and ECO codes A125 to A129 and A200: why the tank goes cold
Element, relay and ECO codes disable the heater entirely, so they are the codes behind a hybrid with no hot water at all. A 4,500 W, 240 V element should read 12.8 ohms with the breaker off and the terminals tested dead (volts squared divided by watts), and Rheem’s chart has the technician take that reading to choose between a new element and a new board, the same check used for testing and replacing a water heater element.
On 208 V, Rheem’s PROPH hybrid spec sheet says element output drops 25%, to 3,375 W. An element shorted to the tank can show up as an element that keeps tripping the breaker rather than as a code. For A200, Rheem says to turn off the breaker if the ECO fails to shut off and to leave wiring, element and safety-device repairs to qualified service personnel.

Where the 2018 Gen 4 manual reads differently
AP18095-2 lists 31 codes against 40 in AP23657, and two codes change meaning between them.
| Code | AP18095-2 (2018) | AP23657 Rev 01 (2024) |
|---|---|---|
| A006 | Elements due to low air flow; check filter, fan and ducting | Elements due to compressor malfunction |
| T005 | Elements due to compressor malfunction | Elements due to low airflow |
| A007, T007 | Compressor Shutdown: Comp.Feedback Failure | Not listed |
| A005, T006, A009 | Not listed | Listed (compressor) |
| A120 to A123, A502, A503, T504, A906 | Not listed | Listed (valve, clock, WiFi, board) |
| Vacation mode tank temperature | About 65°F | About 82°F |
For most codes the 2018 chart’s only action is to call Rheem Tech Support at 1-800-995-0982, with the model, serial number and code ready. Rheem’s 120 V plug-in heat pump manual AP21914 Rev 02 uses the Gen V numbering but drops A008 and the element codes A125 to A129.
E1, E2, HP01 and other codes no Rheem hybrid manual lists
E1, E2, E3, E4, HP01, HP02 and HP10 turn up in search results for Rheem hybrid codes, yet none appears in AP23657, AP18095-2 or AP21914, and the pages publishing them disagree. One appliance blog calls E1 a communication error; a second article on the same site calls it a temperature sensor fault. An HP01 page credited to an “official Rheem service manual” cites a 37 to 120°F ambient rating; Rheem’s spec sheet says 37 to 145°F.
If your display shows a two-character code, you may be reading a different Rheem product. Rheem’s gas tanks report faults by blink count on the gas control, covered in our guide to Rheem’s flash-count codes for gas tanks.
How we sourced this
Sources are Rheem’s US manuals AP23657 Rev 01, AP18095-2 and AP21914 Rev 02 and spec sheets THD-PPEH5-30SO Rev. 8 and the PROPH LeakGuard sheet. Merged table cells were checked against the rendered PDF pages. The 12 and 18 code counts and the 12.8 ohm figure are our arithmetic. Codes found only on third-party sites were kept out of the tables.
Rheem hybrid error code questions
How do you clear an alarm on a Rheem hybrid water heater?
On a Gen V unit press Next until Current Alarm shows, then press the Clear Alarm button. On the 2018 touchscreen, open Service, then alarms, then tap clear alarms. If the fault is still present the same code returns, so clearing only confirms the repair worked.
Why is my Rheem hybrid running on the elements only?
Either someone selected Electric mode, or one of 12 compressor, airflow, sensor or condensate codes is active. Rheem says those codes make the heating source default to the elements. Check Current Alarm first, then confirm the mode shown at the top of the screen.
Can you turn off the beeping on a Rheem heat pump water heater?
Yes. On Gen V units the first item under the Next menu is ALARM BEEP, which you switch from Yes to No with the arrow buttons. The 2018 manual calls the same setting Beep On Alarm. Muting the tone does not clear the code or fix the fault behind it.
Does the Rheem EcoNet app show error codes?
Rheem’s 2018 manual says Wi-Fi brings leak detection alerts and diagnostic alerts to your phone, and the 2024 manual says the leak sensor alerts the EcoNet app. Neither manual prints the app screen, so read the four-character code on the unit itself before calling.