Fleck 5600 Error Codes: Err 0, 1, 2, 3 on the 5600SXT and the Fix for Each
Fleck 5600 error codes appear only on the digital 5600SXT: Err 0 is a cam sense error (the drive took over 6 minutes to reach the next position), Err 1 a cycle step error, Err 2 a regeneration failure after 99 days without one, and Err 3 a control board memory error. The mechanical 5600 shows no codes.
What does each Fleck 5600SXT error code mean, and what fixes it?
Pentair lists four numbered codes and one status code, all shown on the In Service display. The table quotes the troubleshooting page of the Fleck 5600SXT Downflow Service Manual, form 42684 Rev L and splits its recovery steps into the owner’s part and the part the manual sends you to. Upflow manual 42683 Rev J prints the same five rows.
| Code | Pentair’s wording | Likely cause, from the recovery steps | Owner fix | Part or setting to check |
|---|---|---|---|---|
| Err 0 | Cam Sense Error. “The valve drive took longer than 6 minutes to advance to the next regeneration position.” | Cam switch unplugged from the board, worn or misassembled motor or gears, sticking piston | Unplug, plug back in, watch it “cycle to the next valve position and stop” | Drive motor 16944 (24V, 60 Hz, 2 rpm), gears 23045, 13017 and 42933, micro switches 10218, piston |
| Err 1 | Cycle Step Error. “The control experienced an unexpected cycle input.” | Loose or failing cam switch, or a Valve Type (VT) setting that does not match the valve | Step through a manual regeneration with Extra Cycle | Micro switches 10218, cycle cam, VT |
| Err 2 | Regen Failure. “The system has not regenerated for more than 99 days (or 7 days if the Control Type has been set to Day-of-Week).” | Meter not counting, loose meter cable, wrong capacity or Day Override, all seven days OFF | Hold Extra Cycle 5 seconds; the regeneration resets the code | Meter and meter cable, then C, DO and FM settings |
| Err 3 | Memory Error. “Control board memory failure.” | A fault in the control board’s memory | Master reset, reprogram, manual regeneration | The control, if it returns |
| UD | Upper Drive Sync. “Power failure install programming change.” | Power loss, a fresh install or a settings change | Nothing. “Valve will automatically recover.” | None |
The drive motor turns at 2 rpm, so the 6-minute Err 0 limit means about 12 motor revolutions on one position change without the control seeing the step it expected. Err 2 is a clock code, not a hardware code, and Pentair’s recovery steps for it check only the meter and the settings.
Pentair’s homeowner document, the Fleck SXT Controllers Owner’s Manual, form 44001 Rev E, lets the owner clear Err 2 and sends Err 0, 1 and 3 to a water treatment professional. Some dealer pages call Err 1 a motor that runs nonstop and add an Err 4; neither appears in the four Pentair SXT tables read for this page.
Do the 5800 SXT and 9100SXT share the 5600SXT codes?
Yes, the numbers and names match across the SXT family, but the drive hardware does not, so use 5600SXT part numbers only on a 5600SXT.
| Valve and controller | Pentair document read | Codes listed | How the drive position is sensed |
|---|---|---|---|
| 5600SXT downflow | Service manual 42684 Rev L (2018) | 0, 1, 2, 3, UD | Black cycle cam 17438 (blue 40609 on double backwash) read by two micro switches 10218 |
| 5600SXT upflow | Service manual 42683 Rev J (2016) | 0, 1, 2, 3, UD | Yellow upflow cycle cam 24598, red brining cam 17885, same switches 10218 and motor 16944 |
| 5800 SXT | Service manual 43359-01 Rev G (2022), dealer-hosted copy | 0, 1, 2, 3, UD | Wiring diagram labels an optical encoder input; motor is assembly 61835 |
| 2510, 2750, 2850, 9000, 9100 and 9500 SXT | SXT Timer Supplemental Service Manual, P/N 42713 Rev E, dealer-hosted copy | 0, 1, 2, 3 | Separate timer, 42777 on the 9000/9100/9500 twin-tank valves |
| 5600 mechanical | Fleck 5600 Service Manual 40106 Rev N, dealer-hosted copy | None, no display | Program micro switch and wheel pins, with no display to report a fault |
The 5800 SXT manual reuses the 5600SXT recovery text, cam-switch check included, even though its wiring diagram shows an optical encoder input. Share the meanings, not the parts.
Is your Fleck 5600 the digital SXT or the older mechanical timer?
An LCD with three buttons (Extra Cycle, Up, Down) means a 5600SXT. Its front panel is 61672-0201 (square) or 61673-0201 (curved), powered by a plug-in 24V, 9.6VA transformer, 44147.
The mechanical 5600 in manual 40106 has no screen and cannot post a code. It has a manual regeneration knob, a 24-hour gear set with a red button, and a skipper wheel (one tab per day) or, on metered valves, a program wheel with a “people” dial. If it stops regenerating, the manual’s running check is the sight hole in the back of the motor, 18743 on 120V or 19659 on 24V. Step it by turning the knob slowly clockwise, letting the motor stop between pins. For how often a softener should regenerate and what each cycle step does, see our water softener regeneration guide.

Where the drive motor, cycle cam and switches sit in a 5600SXT powerhead
Pentair’s exploded view 61501-56SXT Rev C puts the cycle cam and two micro switches on the front of drive housing 14448-100, behind the front panel, and the motor and gear train on the back, behind cover 40338. A 5600SXT has no encoder; position comes from the cam pressing the switches.
On its 2510SXT and 2750SXT diagrams, SXT supplement 42713 names the pair SW1, valve homing switch, and SW2, valve step switch. The 5600SXT list calls both “Switch, Micro” 10218 on insulator 10302, which is why Err 0 and Err 1 both start with checking every cam switch connection.
How do you clear Err 2 and prove the meter is counting?
Run a full manual regeneration, then confirm the meter registers flow, or Err 2 returns in 99 days. Steps per manual 42684, no tools:
- In service, hold Extra Cycle 5 seconds. The valve drives to backwash (BW), flashing “——” until it arrives.
- Let it run, or press Extra Cycle once per step through BD, RR and BF back to service.
- Open a cold tap; the flow indicator should flash.
- Hold Up and Extra Cycle 5 seconds for Diagnostic mode. FR is current flow rate, VU volume since the last regeneration.
- If FR reads zero with a tap open, reseat the meter cable at the meter module on the valve outlet, then confirm DO is not OFF in User mode.
Hard water after a clean regeneration is a brine problem. Pentair’s chart lists an open bypass and an empty brine tank as the first two causes and warns against granulated or rock salt; check yours against our guide to choosing water softener salt. With no code and hard water, use our checklist for a water softener that is not working.

Soft reset or master reset: which one the 5600SXT manual calls for
Err 3 calls for a master reset. A soft reset (Extra Cycle and Down for 25 seconds) returns parameters to system defaults except volume remaining or days since regeneration; a master reset (hold Extra Cycle while plugging in) resets all of them. Both wipe the dealer’s capacity, hardness and cycle times, so copy them first from the Job Specification Sheet on page 2 of manual 42684. Then:
- Hold Up or Down until TD shows, set 12:01 PM, press Extra Cycle.
- Hold Up and Down together until DF (display format) appears.
- Press Extra Cycle through DF, VT, CT, NT, C, H, RS, SF or RC, DO, RT, cycle times BW, BD, RR, BF, and FM, then once more to save. The chart says changes drop after 60 seconds idle, the text says 5 minutes, so do not pause.
- Reset the clock from 12:01 PM to the real time.
- Run a manual regeneration. A move over 6 minutes now posts Err 0, a drive fault, not memory.
If Err 3 returns, Pentair says unplug and contact technical support. A replacement timer lifts off after the back cover, yoke screw and mounting screws come out; the new main gear’s drive pin must engage the drive yoke slot.
Which 5600SXT settings an owner can change and which belong to the dealer
Owners get five values in User mode; Master Programming carries Pentair’s caution to contact your water dealer first. User mode opens with Up and Down held 5 seconds while the clock is not 12:01 PM: DO (OFF to 99 days), RT, H (1 to 199 grains), RC or SF, and CD.
Master Programming holds VT, CT, capacity, reserve type, cycle times (0 to 199 minutes) and FM. When you call, ask for a micro switch and piston travel check for Err 0 or 1, an FM and meter check for repeat Err 2, and a new timer only if Err 3 survives a master reset.
Before the powerhead comes off, the manual says to bypass, step briefly to backwash to relieve pressure, return to service and unplug; our guide to the water softener bypass valve explains how to find and set it. The manual also requires 20 to 125 psi, water under 110°F and an unswitched outlet, covered in our guide on how to install a water softener.
Fleck 5600SXT error code questions
Will unplugging a Fleck 5600SXT erase its settings?
No. Pentair says the SXT keeps its configuration in non-volatile memory indefinitely, with or without line power. Manual 42684 Rev L says the clock keeps time for at least 8 hours during an outage, and the time of day flashes after a power failure. Press any button to stop the flashing and confirm the clock is right.
What does UD mean on a Fleck 5600SXT display?
UD is Upper Drive Sync. Pentair lists its cause as a power failure, a new installation or a programming change, and the service manual says the valve will automatically recover. The owner’s manual 44001 adds that no action is needed, so there is nothing to reset or reprogram.
Is there an Err 4 on the Fleck 5600SXT?
Not in Pentair’s tables. The 5600SXT manuals 42684 and 42683, the 5800 SXT manual 43359-01 and the SXT timer supplement 42713 all stop at Err 3, plus UD on the valve manuals. If a display shows a code outside that list, read the model label on the control, because it may not be an SXT controller.
Does pressing Extra Cycle once start a regeneration?
One press only queues a regeneration for the programmed regeneration time, and the service icon flashes to show it. A second press cancels the queue. Holding Extra Cycle for 5 seconds starts a regeneration immediately, and that full regeneration is what clears Err 2 on the 5600SXT.
Why does Err 2 keep coming back on a metered 5600SXT?
Pentair’s first check is whether the meter is measuring flow. If it never counts, the control never reaches its capacity, and with day override set to OFF nothing else triggers a regeneration. Open a cold tap and watch for the flow indicator or the FR reading, then check the meter cable and the DO setting. The same logic applies to an empty house: a metered 5600SXT counts no gallons while you travel and regenerates only if a day override comes due, which is why turning a softener off for vacation depends on the control type.
How we sourced this
Everything comes from Pentair documents: 5600SXT manuals 42684 Rev L and Rev K and 42683 Rev J, 5800 SXT manual 43359-01 Rev G, owner’s manual 44001 Rev E, SXT supplement 42713 Rev E and 5600 manual 40106 Rev N. Part positions come from exploded view 61501-56SXT Rev C. The 12-revolution figure is our arithmetic. Rev K says 48 hours of clock backup in one place where Rev L says 8; we used Rev L. Prices, Err 4 and XTR-series codes were left out.