Faucet Leaking From the Handle: Cartridge, O-Ring or Packing Nut? Part Numbers for 8 Faucets
A bathroom faucet leaking from the handle has a failed seal around the valve stem: cartridge O-rings on Moen, Kohler and Pfister cartridge faucets, the cam and packing on Delta ball faucets, or the packing nut and washer on old compression faucets. Identify the faucet type first, then buy that one part.
Moen’s support library puts it plainly: when water leaks from the handle area while the faucet is on, the reason is usually the cartridge, and a single-handle faucet has one cartridge while a two-handle faucet has two. Kohler’s Leaking Under the Handle page, covering centerset, single-hole and widespread lavatory faucets, blames dirt and debris inside the valve and prescribes a new valve or cartridge.
Which of the four faucet types do you have, and which seal leaks at its handle?
Four valve designs cover nearly every sink faucet, and each one leaks at the handle through a different seal. A single lever that lifts for flow and swings for temperature sits on a cartridge or a ball. Two handles that stop hard at a set point use cartridges or ceramic disc valves. Two handles that keep tightening as you close them are compression stems.
Moen’s bathroom cartridge identification guide splits its own single-handle faucets by retainer: a U-shaped copper clip means the 1225, introduced in 1981, while a retainer nut on a faucet built after 2009 means the Duralast 1255, 160657 or 150257, three kits whose nuts are not interchangeable. Since 2015 Moen has used both the 1224 and 1234 in two-handle 4-inch centersets, and those two are not interchangeable either, which is why the old cartridge belongs in your pocket when you walk into the store.
Which part number fixes the handle leak on 8 common faucets?
The table below pairs each faucet family with the part its maker sells for a handle leak and the price on the maker’s own site when we read it on November 17, 2026. None of the top-ranking pages we read list these side by side.
| Faucet | Type | Seal that leaks | Part | Maker price, Nov 17, 2026 |
|---|---|---|---|---|
| Moen single-handle, copper U-clip (1981 on) | Cartridge | Cartridge O-rings | 1225; O-ring and grommet kit 92451 | 1225 $35.88, 92451 $9.28 (moen.com) |
| Moen single-handle, retainer nut (after 2009) | Cartridge | Cartridge seals | 1255 Duralast, nut included | $34.39 (moen.com) |
| Delta single-handle DIAMOND kitchen | Ceramic cartridge | Cartridge seals | RP50587 | $61.68 online, $77.10 list (deltafaucet.com) |
| Delta single-lever ball | Ball | Cam and packing under the cap | RP61 cam assembly; RP4993 seats and springs (2 each) for a spout drip | RP61 $8.08, RP4993 $8.08 online (deltafaucet.com) |
| Delta two-handle with knobs | Stem unit | Stem seals | RP1740 (levers take RP25513, per Delta) | $18.52 online, $23.15 list (deltafaucet.com) |
| Kohler two-handle, 3/4 in. ceramic | Ceramic disc | Valve seals | K-22376 cold, discontinued, replaced by K-1000187 | No web price shown (kohler.com) |
| Pfister two-handle, metal quarter-turn | Cartridge | Cartridge seals | 974-2830 (hot side) | $38.15 list (pfisterfaucets.com) |
| American Standard single control | Cartridge | Cartridge seals | A951470-0070A | $18.85 sale, $29.00 list (americanstandard-us.com) |
Three rows carry traps. Delta’s RP61 page says the cam is now one assembly replacing the old two-piece cam and packing, and that the plastic adjusting ring inside the cap is no longer required with it. Kohler’s K-22376 now forwards to K-1000187, so search Kohler’s parts catalog by your faucet model rather than by the number stamped on an old valve. Pfister’s 974-2830 is a hot-side part, and Pfister warns that hot and cold cartridges can differ because they turn in opposite directions.
A kitchen faucet leaking from the handle uses the same logic with different numbers; our kitchen faucet cartridge replacement guide covers the Moen 1225 pull and the Delta RP50587 in kitchen bodies.

How do you swap a cartridge without cracking it or flooding the vanity?
Close both angle stops, open the faucet to bleed pressure, then pull the handle; Moen’s 1200/1225 sheet INS744F opens with exactly that caution. Pfister’s bathroom faucet leaking guide adds a test for two-handle faucets: close the cold stop first, and if the handle leak stops, only the cold cartridge needs replacing.
- Find the handle fastener. Pfister lists three: a set screw in a small hole at the base (most likely a 3/32 in. Allen key), a screw under a snap cap, or a fixed hub that unscrews counterclockwise.
- Remove the retainer. Moen’s Duralast sheet INS1936B calls for a 3/32 in. hex key and a 13/16 in. wrench. Moen’s newer 202233 and 212555 nuts take tool 118305 or a 7/8 in. socket, and the 2025 cartridge 1269 takes a 25 mm socket or the included tool 228305.
- Pull the cartridge straight up and check the bore for loose springs, which Pfister says some cartridges leave behind.
- Coat new O-rings with silicone grease. Oatey’s plumbing grease guide says silicone is compatible with plastics and rubber, while petroleum grease can degrade both over time; our comparison of silicone versus petroleum plumbers grease lists the products.
- Tighten to the maker’s number, not by feel. INS1936B says hand tight plus 90 degrees (1/4 turn) with a wrench, and to reuse a brass nut but replace a plastic one. Pfister says hand tight plus 1/2 to 1 full turn, and that overtightening can crack the cartridge.
- Set the handle perpendicular to the spout at the off position, per Pfister, then open the stops and run the water for 1 minute before checking under the handle.
How do you stop a compression faucet leaking at the packing nut?
Snug the six-sided packing nut first, because a loose nut is the cheapest handle leak to fix. The Portland Water Bureau’s faucet leak instructions say to wrap the threads under the packing nut with Teflon tape and tighten it gently, never overtightening, and to replace the nylon washer under it if water still escapes. The same page warns that the nut may unscrew in either direction, so reverse the wrench if it will not budge on the first try.
If water comes up along the stem instead, Portland’s steps have you unscrew the stem from the packing nut and replace its O-ring with one of the exact same size. Portland suggests petroleum jelly on that O-ring; Oatey’s guidance above points to silicone grease for rubber, so use silicone. Two-handle tub and shower stems follow the same packing logic deeper in the wall; see our guide to fixing a leaky shower faucet.
How do you fix a Delta ball faucet leaking under the cap?
Replace the cam and packing with the one-piece RP61, which Delta lists at $8.08 online, and remove the old plastic adjusting ring from the cap if it is still there. Delta’s answers on that page say the one-piece part is not meant to separate and has a tab that aligns inside the valve body. If the spout also drips with the lever off, add the RP4993 seats and springs, $8.08 online for 2 of each, while the faucet is apart. That is $16.16 in parts for both leaks.

How much water does a faucet dripping at the handle waste?
At 10 drips per minute a faucet loses about 347 gallons a year, using the USGS assumption of 1/4 mL per drip. The USGS drip calculator sets one gallon at 15,140 drips; the arithmetic below is drips per minute x 1,440 minutes x 365 days / 15,140.
EPA’s Fix a Leak Week page says a faucet dripping once per second wastes more than 3,000 gallons a year, about 44% more than the 2,083 gallons the USGS volume gives at the same rate. Working backward, EPA’s figure implies a drip of about 0.36 mL (3,000 gal x 3,785.41 mL / 31,536,000 drips a year). Many handle leaks only run while the tap is open, as in Moen’s description, so a handle seep wastes less than a spout drip at the same count.
When is a free warranty cartridge or a new faucet the better fix?
Call the maker before buying anything if you are the original owner and still live in the house. Moen’s Lifetime Limited Warranty covers leaks and drips for the original purchaser while they own the home, and Moen says it may send replacement parts free of charge with proof of purchase. Delta’s warranty page promises to repair or replace defective parts free during the warranty, which runs for as long as the original consumer purchaser owns the home, and excludes labor. Pfister’s Pforever Warranty covers finish and function for as long as you own your home, and Kohler says handle-leak parts may be covered under its Faucet Lifetime Limited Warranty.
Replace the whole faucet when the body is cracked or corroded, when the maker no longer lists a valve for your model, or when the parts approach the faucet’s price. Delta lists its B510LF-PPU Foundations single-handle centerset at $80, so Moen’s $34.39 cartridge is 43% of a new faucet, while Pfister’s hot-side 974-2830 alone is 48% at $38.15. Our walkthrough on replacing a bathroom faucet covers the swap if the numbers point that way.
Frequently asked questions about faucet handle leaks
Why does my faucet only leak from the handle when the water is running?
The water is under line pressure only while the valve is open, so a worn O-ring or cartridge seal passes water up past the stem instead of down to the spout. Moen describes exactly this symptom, water from the handle area when the handle is turned on, and names the cartridge as the usual cause.
Do I need to replace both cartridges on a two-handle faucet?
Not always. Pfister’s test is to close the cold stop under the sink first. If the leak stops, only the cold cartridge is bad. If not, close the hot stop. Delta sells the RP1740 as one stem that fits both handles, while Pfister notes hot and cold cartridges can be different parts.
Will Moen or Delta send a new cartridge for free?
Often yes, for the original buyer who still owns the home. Moen says it may send replacement parts free of charge for products under its Lifetime Limited Warranty, and Delta will repair or replace defective parts free during the warranty period. Neither warranty pays a plumber’s labor, and both ask for proof of purchase.
Is a drip from the handle the same as a drip from the spout?
No. A drip from the spout with the faucet off means the valve no longer seals shut, which is a seat, spring or disc problem. Water from under the handle means a seal around the stem or cartridge body has failed. The same cartridge swap often fixes both on Moen and Kohler faucets, but compression faucets need a washer for one and packing for the other.
How we sourced this
Documents checked November 17, 2026: Moen support articles on handle leaks and bathroom cartridge identification, Moen instruction sheets INS744F and INS1936B, maker product and warranty pages for every part in the table; Kohler Assist; Pfister’s leak troubleshooting article; the USGS drip calculator; EPA Fix a Leak Week; Portland Water Bureau repair steps; Oatey’s grease guide. Prices are maker web prices on that date and change often. Computed: annual gallons by drip rate and the drip volume implied by EPA’s figure. Left out: Glacier Bay parts, because Home Depot’s parts pages could not be loaded to confirm a part number or price, and any Moen, Delta or Kohler statement on grease type, which we did not find in their documents.