Bathroom Sink Only Has Cold Water? When One Faucet Has No Hot and How to Fix It
If your bathroom sink only has cold water while the kitchen and shower run hot, the water heater is fine and the fault sits in the last 3 feet, the hot angle stop and the spout: a partly closed stop, a clogged aerator or supply line, a failed or limited cartridge, a mixing valve set low, or crossed supply lines.
Does any other tap in the house run hot?
Run the kitchen sink on full hot for 60 seconds, then the tub in the same bathroom. If both get hot, the heater and the main hot trunk work. If the kitchen is cold too, stop here and work through the checklist for no hot water anywhere in the house.
If the tub in the same room is also cold, the fault is upstream of both fixtures: a closed branch valve, a kinked PEX line or a manifold port. If only the sink is cold, open the vanity doors.
Six causes of a cold-only bathroom sink, checked in order
The table runs from fastest check to slowest, the order Moen gives in its low flow from one side support article: stops fully open, then both supply lines delivering full pressure, then the cartridge. Prices are single public listings checked November 25, 2026.
| Symptom | Likely cause | Check | Fix and part |
|---|---|---|---|
| Hot side trickles or stops; cold is normal; recent work under the sink | Hot angle stop partly closed | Turn the hot stop handle counterclockwise until it stops | Open it. If the handle spins or the stem leaks, replace the stop: BrassCraft OCR19X C, 1/2 in. nominal comp by 3/8 in. OD, listed at $8.86 at SupplyHouse |
| Hot is weak and the stream sprays sideways | Aerator screen clogged with scale or tank sediment | Unscrew the aerator and run full hot for 10 seconds | Clean or replace the aerator; keep the same gpm rating stamped on the old one |
| No hot even with the aerator off | Hot supply line or stop blocked | Bucket test, next section | Replace the braided line or the stop |
| Single handle reaches full hot but water stays cold or lukewarm | Cartridge hot port fouled, or the limit stop set short | Pull the handle; look for a limit ring on the stem | Reset the stop or replace the cartridge, matched to the faucet model: Delta RP50587 DIAMOND 1H cartridge, $61.68 online (list $77.10) at deltafaucet.com |
| Hot comes out with the handle on cold, and the reverse | Supply lines crossed or cartridge stem turned 180 degrees | Feel which braided line is hot after 1 minute of running | Moen 1225: rotate the stem 180 degrees. Moen 1255 or 4000: swap the supply lines |
| Warm but never hot, both handles | Thermostatic mixing valve under the sink set low | Look for a brass body with three ports tied into both supplies | Adjust it within the maker’s range, or have it set by a plumber |
On a two-handle faucet only the hot-side cartridge needs replacing: Delta lists its RP25513 two-handle stem assembly at $35.92 online (list $44.90).
How to bucket-test the hot supply line
The bucket test shows whether hot water reaches the faucet at full flow, Moen’s second check. Close both angle stops clockwise. Put a towel and a 1 gallon bucket or container under the hot side, then loosen the hot braided line’s coupling nut at the faucet tail with an adjustable wrench, holding the tail with a second wrench if it turns. Point the line into the container and open the hot stop fully.
- Time how many seconds the hot line takes to fill the 1 gallon container, then repeat on the cold line.
- Divide 60 by each time in seconds to get gpm. A line filling a gallon in 20 seconds delivers 3 gpm.
- If hot fills about as fast as cold, the stop and line are fine; suspect the cartridge or aerator.
- If hot is a fraction of cold, disconnect the line at the stop outlet and repeat. A strong flow there means the braided line is blocked; a weak flow there means the stop or the pipe behind it.
Both sides start at the same static pressure, so a large gap means a restriction. Our explainer on how much weaker hot pressure can normally run than cold gives the losses a heater adds, so you can tell a normal gap from a blockage.

Cartridge limit stops and reversed stems on Moen and Delta faucets
A cartridge blocks hot through scale in the hot port, a limit stop set toward cold, or a rotated stem. Moen’s 1225 instructions for single-handle bathroom faucets made before 2009 call for pliers, a flathead screwdriver and the plastic twisting tool in the kit: slide out the copper retainer clip, turn the cartridge a quarter turn, raise the stem to its stop and pull. On reinstall the plastic tabs center on the 12 and 6 o’clock cutouts and the stem’s small notch faces forward.
If hot and cold come out reversed on a 1225, Moen says to rotate the stem 180 degrees. On the 1255 and 4000 cartridges Moen’s only fix is to swap the two supply lines. Before swapping, check how the supply lines and tailpieces connect under a bathroom faucet.
Moen’s 1225 article says to clean and flush the valve body before the new cartridge goes in, because grit that fouled the old one will foul the next. If the body is cracked or the cartridge is discontinued, replacing the whole bathroom faucet is faster than hunting parts.
Is a mixing valve under the sink holding the hot down?
A thermostatic mixing valve under a lavatory blends hot and cold to a set outlet temperature, so a sink fed by one runs warm on full hot by design. The Watts LFUSG-B M3 under-sink valve is a typical example: ASSE 1070 listed, 3/8 in. compression ports, adjustable from 80 to 120 F, set to 105 F at the factory, with a 0.25 gpm minimum flow and a 39 to 80 F cold inlet range.
These valves are required in public buildings, not homes. IPC Section 416.5 calls for tempered water at public hand-washing facilities, delivered through a device that conforms to ASSE 1070, and the IPC defines tempered water as 85 to 110 F. The Uniform Plumbing Code states that hot water from public use lavatories is limited to 120 F and that the water heater thermostat does not count as the control. A valve under a home vanity was added by choice, so ask the household before raising it.

How long should hot water take to reach a bathroom sink?
At a 1.2 gpm faucet on full hot, 50 ft of 1/2 in. Type L copper takes at least 30 seconds to purge its cold water. The table computes that floor from the pipe volumes in the ASTM B88 tube dimension table: Type L 1/2 in. holds 0.0121 gal per ft (ID 0.545 in.) and Type M holds 0.0132 gal per ft (ID 0.569 in.). Flow inputs are 1.2 gpm, the maximum in EPA’s December 2024 WaterSense Version 2 draft, and 1.5 gpm, the current WaterSense maximum.
| Hot run, 1/2 in. | Pipe volume, Type L | Full hot, 1.2 gpm | Full hot, 1.5 gpm | Handle at middle, 0.6 gpm hot | Type M, full hot 1.2 gpm |
|---|---|---|---|---|---|
| 25 ft | 0.30 gal | 15 s, 0.30 gal wasted | 12 s | 30 s, 0.61 gal wasted | 17 s, 0.33 gal |
| 50 ft | 0.61 gal | 30 s, 0.61 gal wasted | 24 s | 61 s, 1.21 gal wasted | 33 s, 0.66 gal |
| 75 ft | 0.91 gal | 45 s, 0.91 gal wasted | 36 s | 91 s, 1.82 gal wasted | 50 s, 0.99 gal |
Method: seconds = run length x gal per ft / hot-side gpm x 60. At mid-handle, assumed a 50/50 mix, hot flow halves, so the purge takes twice as long and twice the water goes down the drain. These are minimums, because the pipe absorbs heat first.
Judge the delay on full hot, never mid-handle. A sink still cold after 2 minutes on full hot is not waiting on pipe volume, since 2 minutes at 1.2 gpm moves 2.4 gallons, 8 times what 25 ft of Type L holds. The model codes also cap the run: IPC Section 607.2 limits uncirculated hot piping to 50 ft from source to fixture, and the 2021 IRC added Section P2905.3 at 100 ft, per the ICC Building Safety Journal.
Why a tankless heater can leave one low-flow sink cold
A tankless heater fires only above its activation flow, and a low-flow lavatory on a mixed setting can sit below it. Rinnai’s RU series indoor spec sheet lists a 0.26 gpm minimum flow for the RU199i, RU180i, RU160i and RU130i and 0.4 gpm to activate. Navien’s NPE-2 quick facts list 0.5 gpm, with a below 0.01 gpm option only on NPE-A2 models set to ComfortFlow recirculation mode.
| Faucet flow | Hot share needed, Rinnai 0.4 gpm activation | Hot share needed, Navien 0.5 gpm minimum |
|---|---|---|
| 1.5 gpm (WaterSense maximum) | 27% | 33% |
| 1.2 gpm (Version 2 draft) | 33% | 42% |
| 0.8 gpm (WaterSense minimum at 20 psi) | 50% | 63% |
Method: hot share = heater threshold gpm / faucet gpm. A 1.2 gpm faucet on a Navien NPE needs the handle at least 42 percent of the way toward hot just to fire the burner, and a partly clogged aerator that drops the faucet to 0.8 gpm raises that to 63 percent. Test it: open the handle fully to hot; if the sink then runs hot, clean the aerator instead of buying a cartridge.
Questions about a bathroom sink with no hot water
Can a bad cartridge cause no hot water in only one sink?
Yes. A single-handle cartridge meters both ports, so scale or a broken seal on the hot inlet blocks hot at that faucet only. Moen says to remove and replace the cartridge and flush the valve body once both stops and both supply lines prove full flow.
Why does my bathroom sink get warm but never hot?
Look for a thermostatic mixing valve under the sink or a limit stop on the cartridge. A Watts LFUSG-B M3 leaves the factory at 105 F and adjusts from 80 to 120 F, so a sink fed by one will never match the kitchen at a 120 F heater setting.
Do I need a plumber if only the bathroom sink has no hot water?
Usually not for the first four checks, which need a towel, a bucket and pliers. Call one if the hot angle stop handle spins without opening, if the stop leaks at the stem after you turn it, or if the bucket test shows the hot line itself is starved before the stop.
Is there a law limiting hot water temperature at a home bathroom sink?
The lavatory limits in the model codes target public hand-washing facilities. IPC Section 416.5 calls for an ASSE 1070 device there, and the Uniform Plumbing Code caps public lavatories at 120 F. A private home sink gets whatever the heater delivers unless a mixing valve was added.
Will a recirculation pump fix a sink that takes too long to get hot?
It fixes delay, not blockage. A pump keeps the hot line full of hot water so the wait drops toward the few seconds the faucet tail holds. If the bucket test shows weak hot flow, a pump will not help, because the restriction is still in the stop, line or cartridge.
How we sourced this
Documents read: Moen support articles (one-side low flow, reversed hot and cold, 1225 bathroom cartridge); Delta parts pages; the Watts LFUSG-B M3 page; Rinnai and Navien spec sheets; EPA WaterSense faucet documents; ASTM B88 tube dimensions; PHCP Pros on ASSE 1070, IPC 416.5 and the UPC; and ICC on IRC P2905.3. Computed: purge times, wasted water and tankless hot-share thresholds, with inputs shown. Prices are single listings checked November 25, 2026. Left out: Kohler lavatory cartridge part numbers and prices, and a Moen 1225 price, because no maker page could be opened.